LIFECOM's Calibration Lab is now...
ANSI/NCSL Z540, ISO 10012-1 STANDARDS COMPLIANT


•EAGLE
1 to 6 Gas Portable Monitor
Simultaneous detection of up to 6 different gases
  • Wide variety of field proven gas sensors available
  • IR Sensors available for CO2 , % LEL CH4 , and 0-100% volume CH4
  • Transformer testing version available
  • PPM / LEL hydrocarbon detection
  • Powerful long-life pump with125’ range
  • Low flow pump shut off and alarm
  • Methane elimination switch for environmental use
  • Security "Adjustment Lockout Switch"
  • Up to 30 hours of continuous operation
  • Alkaline or Ni-Cad capability
  • Ergonomic RFI/EMI/Chemical resistant case
  • Datalogging option
  • Autocalibration

The EAGLE’s ergonomic design offers easy access to controls such as autocalibration, alarm silence, demand zero, peak hold and a wide variety of other features. Each channel has 2 alarm levels plus TWA and STEL alarms for toxic channels. Alarm levels are adjustable and can be latching or self resetting.
Standard features on the EAGLE are not available on most other competitive units such as PPM/LEL hydrocarbon detection (5 ppm resolution) and a methane elimination switch for environmental applications. For quick response and recovery, the EAGLE has a strong internal pump which can draw samples from over 125 feet.

The EAGLE will con-tinuously operate for over 30 hours on alkaline batteries or 18 hours on Ni-Cads. Many accessories such as long hoses, special probes, datalogging, continuous operation adapters, remote alarms and strobes, dilution fittings, inter-nal hydrophobic filter, etc, are available to help satisfy almost any application. Rugged, weatherproof, easy to operate and maintain, the EAGLE is the industry’s answer to portable gas detection.

Enclosure Weather resistant, chemical resistant, RF/EMI coated high impact polycarbonate polyester blend. Can be set in rain or into 2.5 inches of water without damage. Ergonomically balanced with rugged top mounted handle.
Dimensions 10.5" long x 5.9" x 7" tall
Weight 5 lbs.
Detection Principle Catalytic combustion, electrochemical cell, galvanic cell, and infrared.
Sensor Life 2 years under normal conditions.
Sampling Method Powerful, long-life pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH.
Display 4 x 20 LCD readout with backlighting. Viewed through window in case top. Displays readings & status of all channels simultaneously.
Alarms 2 alarms per channel plus TWA and STEL alarms. Fully adjustable for levels, latching or self reset and silenceable.
Alarm Method Buzzer 85dB at 30 cm, dual high intensity LED’s, and blinking display.
Controls 6 external push buttons for operation, demand zero, and autocalibration. Buttons also access LEL/ppm, alarm silence, peak hold, TWA /STEL values, battery status and many other features.
Continuous Operating Hours 30 hours minimum using alkaline batteries, or 18 hours using Ni-Cads.
Power Source Size D batteries, 4 alkaline or Ni-Cad. Charger has alkaline recognition to prevent battery damage if alkalines are charged.
Operating Temp. & Humidity -10°C to 40°C (14°F to 104°F), 0 to 95% RH, non-condensing.
Indication Accuracy Maximum variance +/- 5% of full scale.
Response Time 30 seconds to 90% (for most gases).
Safety Design Intrinsically Safe, Class I, Division 1, Groups A, B, C and D. CSA / NRTL & UL Classified (most versions).
Standard Accesories Shoulder strap, alkaline batteries, hydrophobic probe, and 5 foot hose (for special toxic gas versions, shorter teflon hose used without probe).
Optional Accessories • Datalogging of up to 4 gases (No datalogging possible on 5 or 6
gas versions or versions with more than 2 toxic sensors)
• Remote alarm
• Dilution fitting (50/50)
• Ni-Cad batteries
• Battery charger, 115 VAC, 220 VAC, or 12 VDC
• Continuous operation adapter, 115 VAC or 12 VDC
• Extra loud buzzer
• Extension probes
• Internal hydrophobic filter (strongly recommended)
Warranty One year material and workmanship
Standard Confined Space Gases
Hydrocarbons 0 - 100% LEL
0 - 50,000 ppm
Oxygen (O2 ) 0 - 40% Vol.
Carbon Monoxide (CO) 0 - 500 ppm
Hydrogen Sulfide (H2S) 0 - 100 ppm
Super Toxics and Other Gases
Ammonia (NH3 ) 0 - 75 ppm
Arsine (AsH3 ) 0 - 1 ppm
0 - 200 ppb
Carbon Dioxide (CO2 ) (I R Sensor) 0 - 5,000 ppm
0 - 10,000 ppm
0 - 5% Vol.
0 - 20% Vol.
0 - 50% Vol.
Chlorine (Cl2 ) 0 - 3 ppm
Chlorine Dioxide (ClO2 ) 0 - 1 ppm
Fluorine (F2 ) 0 - 5 ppm
Hydrogen Fluoride (HF) 0 - 9 ppm
Hydrogen Chloride (HCl) 0 - 15 ppm
Hydrogen Cyanide (HCN) 0 - 30 ppm
Methane (CH4 ) (I R Sensor) 0 - 100% LEL
0 - 100% Vol.
Nitrogen Dioxide (NO2 ) 0 - 15 ppm
Ozone (O3 ) 0 - 1 ppm
Phosphine (PH3 ) 0 - 1 ppm
Silane (SiH4 ) 0 - 15 ppm
Sulfur Dioxide (SO2 ) 0 - 30 ppm
The EAGLE can be provided with up to 6 gas
sensors (4 Toxics maximum). Please specify
gas combination when ordering.

GX-2003 Model
Gas Protection for life
Compact size, weighs only 11 ounces
  • Monitors Combustibles, O2, CO, and H2S
  • 0 to 100% volume Methane, Isobutane, and Hydrogen
  • Auto-ranging display of % volume and % LEL
  • Internal sample drawing pump with 50 foot range
  • Vibration, visual, and audible alarm types
  • Automatic backlight during alarms
  • Calibration reminder and lock out
  • Ni-Cad or alkaline power source
  • Battery pack charges in or out of the instrument
  • Quick charge (complete charge in 90 minutes)
  • Glove friendly glow in the dark buttons
  • Alarm latching or non latching
  • High impact rubber boot protection
  • Up to 600 hours of datalogging with alarm trends
  • Logs last 20 calibration events
  • Autocalibration or single calibration
  • TWA and STEL readings with lunch-break mode
  • Intrinsically safe, CSA, C / US approved
  • 2 year warranty
Applications
  • Utilities
  • Personal monitoring
  • Confined space entry
  • Refineries / petrochemical
  • Chemical plants
  • Hazardous material
  • Water / wastewater treatment
  • Fire services
  • Mining

Built around our high-quality micro-sensor technology, the GX-2003 is RKI’s smallest personal 5-in-1 gas monitor with a built in sample pump. Weighing only 11 ounces, it has many features which set the GX-2003 apart from the competition. For example, it can monitor the standard confined space gases (LEL combustibles, Oxygen deficiency, Carbon Monoxide, and Hydrogen Sulfide), however it can also measure 100% volume combustibles and dynamically display either % LEL, or % volume with its auto-ranging ability.
The GX-2003 is equipped with datalogging and a sizable memory capacity of up to 600 hours of log time. With this much capacity, the GX-2003 can store 100 alarm events, 100 trouble events, the last 20 calibrations, and up to 8 alarm trends where data is collected automatically every 5 seconds for 30 minutes before and after an alarm occurs. Calibration intervals and reminders are user adjustable and can be set to either go into alarm or to lock the user out of normal measurement mode once a calibration period has expired. Calibrations can be performed on all channels automatically or individually in single calibration mode. The GX-2003 is also compatible with the Data Cal 2000 calibration station for simultaneous, hands-free service of up to 10 instruments.

Gas Detected
All Combustible Gases (Methane as standard)
% Volume Methane
Oxygen (O2)
Hydrogen Sulfide
(H2S)
Carbon Monoxide
(CO)
Detection Principle Catalytic combustion Thermal conductivity Galvanic cell Electrochemical cell
Detection Range 0~100% LEL 0~100% Vol. 0~40.0% Vol. 0~100 ppm 0~500 ppm
Sampling Method Internal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter
Display Digital LCD with 7 segments, auto backlight during alarm
Preset Alarms (User Adjustable)
1st alarm 10% LEL
2nd alarm 50% LEL
Over alarm 100% LEL
N/A
Low alarm 19.5%
High alarm 23.5%
Over alarm 40.0%
1st alarm 10 ppm
2nd alarm 30 ppm
TWA alarm 10 ppm
STEL alarm 15 ppm
Over alarm 100 ppm
1st alarm 25 ppm
2nd alarm 50 ppm
TWA 25 ppm
STEL alarm 200 ppm
Over alarm 500 ppm
Alarm Method
Gas alarms: 1st and 2nd (user adjustable), STEL, TWA and OVER
Trouble alarms: Sensor connection, low battery, low flow, circuit trouble and calibration error
Types of Alarms
Gas alarms: Flashing lights, two tone buzzer, and vibration
Trouble alarms: Flashing lights, trouble displayed, intermittent buzzer, and vibration
Operating Temp. & Humidity -20° C ~ + 50°C (-4 to 122°F), 0 to 85% RH, non-condensing
Response Time Within 30 seconds (T90)
Continuous Operation Alkaline battery: 14 hours
Ni-MH battery: 16 hours (fully charged)
Power Source Ni-MH battery pack, direct or separate charge, or 3 AA Alkaline dry cell batteries; interchangeable
Safety Design CSA classified, “C/US”, as intrinsically safe. Class I, Division 1, Groups A, B, C, D
Dimensions & Weight Approx. 171 (H) x 65 (W) x 39 (D) mm (5.6"H x 2.5"W x 1.5"D), approx. 310 g (11 ounces)
Case Material Dust & splash resistant. RFI shielded high impact plastic with protective rubber boot
Controls Five buttons: POWER / ENTER, DISPLAY, AIR, RESET, SHIFT (glow in the dark)
Warranty Two years material and workmanship
Standard Accessories
  • Wrist strap
  • 10" Probe
  • Rubber boot
  • 10’ Hose
  • Manual
  • Training CD
  • Quick reference card
Standard Accessories
(Leak Check/ Bar Hole Versions)
  • Wrist strap
  • Rubber boot
  • Manual
  • Training CD
  • Quick reference card
  • 10" Probe
  • 3' Hose
  • 10' Hose
  • 30" Bar hole probe
Optional Accessories
  • Datalogging software
  • Calibration kit
  • Data Cal 2000 or SM-2003 calibration stations
  • Sample draw hoses (10 standard, up to 40 max. available)
  • AC or DC Charger
  • Ni-MH battery pack
  • Carrying case
Configurations 3, 4, or 5 sensor units
Ni-MH or alkaline battery options
Warranty Two years material and workmanship
*Specifications subject to change without notice.

GX-2001
4 Gas Personal Monitor
Simultaneous detection of 4 gases
LEL, O2, H2S, & CO
  • Smallest 4 gas monitor on the market 2.8" H x 2.2" W x 1.1" D, 6 oz
  • Vibration alarm
  • Alarm trend data
  • Datalogging standard
  • Autocalibration
  • Ni-Cad batteries recharge in 90 minutes
  • Continuously operates for up to 10 hours
  • Large LCD display screen
  • Automatic backlighting at alarm
  • High impact, RFI shielded body
  • STEL and TWA readouts
  • Peak hold readouts
  • Continuously displays current time
  • Intrinsically safe, CSA, C / US approved
  • 2 year warranty After 60 years of breakthroughs in gas detection and sensor technology

RKI is proud to introduce the smallest and most affordable 4-gas monitor in the world, the GX-2001. Weighing only 6 ounces and about the size of a pager (2.8" H x 2.2" W x 1.1" D), the GX-2001 simultaneously monitors combustibles, oxygen, carbon monoxide, and hydrogen sulfide. The GX-2001 is armed with standard features like autocalibration, datalogging, rechargeable Ni-Cad batteries, a unique vibration alarm, STEL / TWA readings, peak hold and auto backlighting at alarm on a large LCD display, and it even tells the time. All of these controls and features are operated through 3 simple glow in the dark buttons. Utilizing either of the GX-2001's chargers, the standard charger or datalogging / charger station, it's Ni-Cad batteries will fully recharge in 90 minutes. Also available is the datalogging software program which is Windows 95, 98, ME compatible.
The GX-2001 is also designed around the world’s smallest gas sensors. Utilizing catalytic combustion, electrochemical and galvanic sensor technologies, each miniaturized sensor is manufactured with the same high quality control that has made Riken sensors and instruments the most reliable and long lasting monitoring devices in the industry

Gas Detected
Combustible Gases (Methane cal standard)
Oxygen (O2)
Hydrogen Sulfide (H2S)
Carbon Monoxide (CO)
Detection Principle Catalytic combustion Galvanic cell electrochemical cell
Detection Range (Increments) 0~100% LEL (1% LEL) 0~40.0% Vol. (0.1% Vol.) 0~100.0 ppm (0.5 ppm) 0~500 ppm (1ppm)
Sampling Method Diffusion sampling, attachable sample drawing pump (RP-6) and hand aspirator optional
Display Digital LCD with 7 segments, auto backlight at alarm display automatically cycles every 3 seconds reading each gas, immediate reading for alarm condition
Preset Alarms (User Adjustable)
1st alarm 10% LEL
2nd alarm 50% LEL
Over alarm 100% LEL
Low alarm 19.5%
High alarm 23.5%
Over alarm 40.0%
1st alarm 10 ppm
2nd alarm 30 ppm
TWA alarm 10 ppm
STEL alarm 100 ppm
1st alarm 25 ppm

2nd alarm 50 ppm

TWA 25 ppm

STEL alarm 400 ppm

Over alarm

Kinds of Alarms
Gas alarms: 2 increasing alarms, STEL, TWA, over scale

Trouble alarms: Sensor connection, low battery, circuit error, calibration range error

Display of Alarm
Gas alarm: Blinking LEDs, intermittent buzzer, blinking gas value, vibration
Trouble alarm: Blinking LEDs intermittent buzzer, display of error message
Special Functions
Manual back light LCD (Automatic at alarm)
STEL, TWA
Peak hold
Continuous display of current time
Autocalibration
Data logging (40 hours)
Alarm trend
Direct charging
Operating Temp. & Humidity -20°C~+40°C (-4 to 104°F), 0 to 85% RH, non-condensing
Response Time Within 30 seconds (T90)
Continuous Operation Up to 18 hours
Power Source Direct charging Ni-MH battery pack, (2.4VDC)
Safety Design CSA classified, "C/US", as Intrinsically Safe. Exia. Class I, Groups A, B, C, & D. Class I, Zone 0, Group IIC. Temperature Code T3C.
Dimensions & Weight Approx. 72 (H) x 56 (W) x 27 (D) mm (2.8” H x 2.2” W x 1.1” D), approx. 140 g (6 ounces)
Case Material Dust & weather resistant. RFI shielded high Impact plastic and stainless steel
Controls Three glow in the dark buttons: POWER / MODE, DISP, AIR
Warranty Two year material and workmanship
Required Accessories Battery Charger or Datalogging / Charger Station with cable and software for datalogging
Optional Accessories
(1) Charging station with PC communication function for datalog downloading
(2) Communication computer cable
(3) Communication software (Windows 95, 98, & NT)
(4) Automatic calibration station
(5) Remote Sample Drawing Pump, RP-6 Model
(6) Hand aspirated sample draw with hose and probe

01 Series
Single Gas Personal Monitors
Single gas detection
  • 4 Gases to choose from: LEL, CO, H2S, or O2
  • Operates 3,000 hrs. on alkaline batteries
    (16 hours for LEL version)
  • Pocket size 1.4”(W) x 4.1”(H) x 0.8”(D)
  • Light weight 3.5 ounces
  • Audible / visual / vibration alarms
  • Special low temp H2S version operates at -40°C
  • Automatic backlight during alarm
  • Peak Hold, STEL & TWA
  • Low battery alarm
  • Impact and water resistant
  • Intrinsically safe, CSA, C / US classified
  • 2 year warranty

Applications

  • Hazardous Material
  • Mining
  • Refineries / Petrochemical
  • Water / Wastewater Treatment
  • Pharmaceuticals
  • Utilities
  • Chemical Plants
  • Fire Services

Individuals need personal protection in hazardous areas at all times without adding extra bulky equipment, and the 01 Series can provide that kind of protection at an affordable price. The GP-01, OX-01, CO-01, HS-01 and HS-01S models are personal single gas monitors designed for personal protection from combustible hydrocarbons, oxygen deficiency, hydrogen sulfide, or carbon monoxide. Each model is controlled by a microprocessor for reliability and advanced capabilities. Each model can be operated continuously for at least 3,000 hours on (2) AAA size alkaline batteries except the GP-01, which operates for 16 hours. The 01 models have 2 preset alarms that are user adjustable and each version is also equipped with visual, audible, and vibration alarms as standard. The replacement sensors are inexpensive, easily field replaceable, have a life expectancy of 2 years, and are interchangeable with other RKI monitors such as the GX-2001, GX-2003, and GasWatch 2 models. The entire 01 Series monitors are safe for use in hazardous locations, classified as intrinsically safe by CSA to U.S. and Canadian standards for Class I, Division 1, Groups A, B, C, and D atmospheres. For additional information please contact one of our reps.

Model Name
OX-01 CO-01 HS-01 HS-01S GP-01
Gas Detected
Oxygen (O2)
Carbon Monoxide (CO)
Hydrogen Sulfide (H2S)
Combustible gas
Detection
Principle
Galvanic cell
electrochemical
Catalytic combustion
Detection
Range
0 – 40%vol.
(0.1%vol.)
0 – 500 ppm
(1 ppm)
0 – 100 ppm
(0.5 ppm)
0 – 100% LEL
(1% LEL Increments)
Alarm Set Points Low 19.5%vol.
High 23.5%vol.
Over 40.0%vol.
1st 25 ppm
2nd 50 ppm
TWA 25 ppm
STEL 200 ppm
Over 500 ppm
1st 10 ppm
2nd 30 ppm
TWA 10 ppm
STEL 15 ppm
Over 100 ppm
1st alarm 10% LEL
2nd alarm 50% LEL
Over alarm 100% LEL
Types of Alarms
    Gas alarms: 1st and 2nd (user adjustable), OVER alarm, STEL and TWA
    Trouble alarms: Sensor connection, low battery circuit failure, and calibration range error
Alarm Indication
    Gas alarm: Flashing LED's, intermittent buzzer, flashing gas value, and vibration
    Trouble alarm: Flashing LED's, intermittent buzzer, and display of error message
    STEL & TWA alarms: Flashing LED's, intermittent buzzer, flashing gas value, and vibration
Preset Alarms
(User Adjustable)
Diffusion
Response
Time
T90 in 30 seconds
(alarms within 5
seconds when
exposed to 12% O2)
T90 in 30 seconds
Accuracy +/- 0.5%vol. +/- 5 ppm
(up to 150 ppm)
+/- 1.5 ppm (up to 30 ppm)
+/- 5% of full scale
Power Alkaline dry cell (2-AAA size)
Alkaline dry cell
Ni-Cad battery pack
Continuous
Operation
Alkaline dry cell: more than 3,000 hours
(at 25°C, no backlight)
1,500 hours at -40°C
Alkaline: 16 hours
Ni-Cad: 8 hours
Safety CSA classified, "C/US", as intrinsically safe. Class I, Div. 1. Group A, B, C & D
Dimension &
Weight
1.4”W x 4.1”H x 0.8”D, (35 x 105 x 20mm); 3.5 ounces (100g)
Display 7-segment + symbol on digital LCD, auto backlighting during alarm
Special Functions Manual backlight for LCD (automatically lit during alarm)
Peak hold, STEL & TWA
Operating Temp.
& Humidity
-4°F ~ 122°F (-20°C ~ 50°C);
Humidity below 90% RH (non-condensing)
-40°F ~ 122°F
(-40°C ~ 50°C);
Humidity below 90%
RH (non-condensing)
-4°F ~ 122°F
(-20°C ~ 50°C);
Humidity below 90%
RH (non-condensing)
Standard
Accessories
Rubber protective boots
Belt clip or alligator clip
Wrist strap
Alkaline batteries
Optional
Accessories
Calibration cap (adapter)
Charger unit
Calibration kit
Ni-Cad battery pack
Warranty
Two years material and workmanship

Fixed System Controllers
Beacon 800
8 Channel Wall Mount Controller
Low cost versatile solution!
  • Capable of up to 8 separate channels
  • Digital display of all 8 channels simultaneously
  • Compact, weatherproof, NEMA 4X enclosure
  • 115 VAC or 24 VDC operation
  • Long life sensors (2+ years typical)
  • Accepts any 4-20 mA transmitter
  • Audible alarm with reset button
  • Two programmable alarm levels per channel
  • Common alarm and fail relays
  • Relay rating 10 amps, form C
Industry Applications
  • Petrochemical plants
  • Refineries
  • Water & wastewater treatment pants
  • Pulp & paper mills
  • Gas, telephone, & electric utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
  • HVAC Gas detection should not be complicated. The Beacon™ 800 is gas detection simplified.

The Beacon™ 800 is a simplified, versatile, low cost fixed system controller for one to eight points of gas detection. It is microprocessor controlled and is capable of accepting up to 8 separate 4-20 mAsensor transmitters which can be either 2 or 3 wire. The Beacon™ 800 can be powered by either 24 VDC or 115 VAC. It is simple to operate and comes complete with a wall mount installation kit.

Physical
Dimensions
Height: 12.5" 318 mm
Width 11.0" 279 mm
Depth 6.4" 163 mm
Enclosure Wall mounting grey polycarbonate with hinged cover.
Conduit
Connection
3/4" NPT conduit hubs, 4 provided for sensors, power and relay wiring
Wiring
Termination
Screw type terminal block, 14 gauge max.
Operating Environment
Operating Temp 14°F to 122°F (-10°C to 50°C)
Storage Temp -4°F to 158°F (-20°C to 70°C)
Relative
Humidity
0 - 100% RH
Relative
Humidity
NEMA-4X enclosure, waterproof, chemical, and weather resistant.
Inputs
4-20 mA Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI sensors are available with
4-20 mA signals. Wiring distances up to 8,000 feet.
Outputs
Relays
    2 relays per channel 10 amp rating, SPDT isolated contacts.
    1 set of common relays:
    2 for gas alarm levels
    1 for malfunction
    Relays fully programmable for:
    Increasing or decreasing alarms
    Latching or self reset
    Normally energized or normally de-energized
    Time delay for alarm on and alarm off
24 VDC 24 VDC output provided to operate sample drawing adapters.
Display 2 alphanumeric displays with backlighting. 16 characters per line; 4 lines each. All 8 channels continuously displayed.
Audible
    Built-in audible alarm, 94 dB, mounted on enclosure.
    Coded Output:
    pulsing = gas alarm
    steady = Fail
Visual 4 visual LED alarms on front cover for alarm indications, pilot, and malfunction.
Optional
Expansion Cards
Individual 4-20 mA (or 1 - 5 VDC) outputs
Expansion Cards Heavy duty relay card (4 each @ 30 amps)
Power
85-264 VAC or 24 VDC standard
Battery backup option available
Approvals
CSA Certified to CSA C22.2 No. 1010 and ANSI/ISA S82.01
Warranty
One year materials and workmanship.

Beacon 110
Single Channel Wall Mount Controller
Low cost versatile solution!
  • Low cost versatile solution
  • Compact, weatherproof, NEMA 4X enclosure
  • 115/220 VAC or 24 VDC operation
  • Long life sensors (2+ years typical)
  • Accepts RKI LEL/O2/H2S/CO direct connect sensors
  • Accepts any 4-20 mA transmitter
  • Audible alarm with reset button
  • Two programmable alarm levels
  • Built-in trouble alarm with relay
  • Relay rating 10 amps, form C
  • Provides 4-20 mA output
Industry Applications
  • Refineries
  • Water & wastewater treatment pants
  • Pulp & paper mills
  • Gas, telephone, & electric utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
  • HVAC

Gas detection should not be complicated. The Beacon 110 is gas detection simplified.

The Beacon 110 is a powerful, low cost fixed system controller for one point of gas detection. It is microprocessor controlled, versatile, simple to install and operate, and priced to be the industry’s best value single gas detection controller. It is capable of accepting RKI sensors directly for LEL level combustibles, Oxygen, Hydrogen Sulfide, or Carbon Monoxide. The Beacon 110 can also accept any 4-20 mA transmitter (2 or 3 wire, 24 VDC). Sensors can be mounted directly at the Beacon 110 housing, or can be wired remote from the controller.

The 10 amp rated relays are strong enough to directly power external alarms and horns. The digital display has backlighting and simultaneous readout of the gas type and concentration.

The Beacon 110 is also housed in a NEMA 4X rated case for a weather tight seal. This case design complies with lock out / tag out standards and can be fully secured. An external reset switch allows the alarm to be silenced from outside of the controller housing. The Beacon 110 ships complete with a wall mounting kit for easy installation.

RKI offers the industry’s widest selection of standard and toxic gas detection sensors, which can be utilized with the Beacon 110, providing gas monitoring protection for almost any application.

Physical
Dimensions
Height: 8.5" 216 mm
Width 7.0" 178 mm
Depth 4.3" 109 mm
Enclosure Wall mounting grey polycarbonate with hinged cover.
Conduit
Connection
3/4" NPT conduit hubs, 4 provided for sensors, power and relay wiring
Wiring
Termination
Screw type terminal block, 14 gauge max.
Operating Environment
Operating Temp 14°F to 122°F (-10°C to 50°C)
Storage Temp -4°F to 158°F (-20°C to 70°C)
Relative
Humidity
0 - 100% RH
Relative
Humidity
NEMA-4X enclosure, waterproof, chemical, and weather resistant.
Inputs
Direct Wired
Sensors
LEL
Oxygen
Carbon Monoxide
Hydrogen Sulfide
Remote amp not required for less than 500 feet..
4-20 mA Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI sensors are available with
4-20 mA signals. Wiring distances up to 8,000 feet.
Sampling Methods Diffusion and sample draw heads available.
Outputs
Relays
    3 relays - 10 amp rating (at 115 VAC), SPDT isolated contacts.
    2 relays for gas alarms and 1 trouble relay.
    Relays fully programmable for: increasing or decreasing alarm, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off
4-20 mA Signal output, 4-20 mA (maximum load impedance 500 ohms), per channel
24 VDC 24 VDC output provided to operate sample drawing adapters.
Display 2 x 8 Alphanumeric display with backlighting.
Audible
    Built-in audible alarm, 94 dB, mounted on enclosure Coded output: pulsing = gas alarm, steady = fail
Visual 3 LED’s on the front cover for alarm status indication, and malfunction
Optional
Expansion Cards
Individual 4-20 mA (or 1 - 5 VDC) outputs
Expansion Cards Heavy duty relay card (4 each @ 30 amps)
Power
Universal 115 VAC & 220 VAC, or 24 VDC nominal, battery backup option available
Warranty
One year materials and workmanship.

•Beacon 410
Four Channel Wall Mount Controller
Features
  • Simultaneously monitor up to 4 channels
  • Digital display of all 4 channels
  • Accepts direct connect sensors for LEL / O2 / H2S / CO / CO2
  • Accepts any 4-20 mA transmitter, 2 or 3 wire
  • 3 programmable alarm levels per channel
  • Up to 3 configurable alarm relays per channel
  • Zero follower automatically compensates sensor drift
  • 4-20 mA analog & Modbus digital output standard
  • 115 / 220 VAC or 24 VDC operation
  • Audible alarm with silence feature
  • Alarm reset switch
  • Built in trouble alarm with relay
  • Weather proof NEMA 4X enclosure
  • Optional strobe & battery backup available
Industry Applications
  • Petrochemical plants
  • Refineries
  • Water & wastewater treatment pants
  • Pulp & paper mills
  • Gas, telephone, & electric utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
  • HVAC

The Beacon 410 is a highly configurable, microprocessor-based, flexible and easy to use 4 channel gas monitor. It simultaneously displays the gas type, readings, and status for 4 channels of gas detection. It can monitor any combination of direct connect sensors (LEL combustibles, Oxygen, Hydrogen Sulfide, Carbon Monoxide, and Carbon Dioxide) as well as any 4-20mA transmitters.

Each channel has 3 fully configurable alarm points. A built-in silenceable audible alarm alerts you to alarm conditions. Each channel also has 2 dedicated fully configurable relays and there is a bank of common relays as well. The common relays can optionally be configured as additional channel relays allowing up to 3 alarm relays per channel.

Each channel provides a 4-20mA output signal. A digital Modbus interface for remote logging of data via a Modbus network is standard. A Min-Max feature retains high & low peak readings for review at any time.

Field calibration is made simple by the easy to use Calibration Mode. A fully configurable high visibility strobe is available as an option. The unit can be powered from 115/220 VAC, an external 24 VDC source, or a 24 VDC backup battery. A trickle charging battery backup feature is also available as an option.

All features and functions of the Beacon 410 are controlled by easy to use menus on the backlit LCD display. The form-C (SPDT) relay contacts are rated at 10A, 250V, reducing or eliminating the need for additional slave relays. All features of the Beacon 410 are built into the unit so you never need to purchase or maintain any “add-on” cards or components.

Physical
Dimensions
Height: 12.5”
Width 11”
Depth 6.4”
Enclosure NEMA 4X non-metallic for indoor and outdoor locations
Conduit
Connection
3/4” NPT conduit hubs, 4 provided, for sensor, power, & relay wiring
Wiring
Termination
Screw type terminal block, 14 gauge max.
Controls
Display PCB Control Switches:
  • UP/YES push button switch
  • DOWN/NO push button switch
  • ESCAPE push button switch
  • ENTER push button switch
  • External reset switch
  • On/Off toggle switch
Operating Environment
Operating Temp 14°F to 122°F (-10°C to 50°C)
Storage Temp -4°F to 158°F (-20°C to 70°C)
Relative
Humidity
0 - 95% RH(non-condensing)
Relative
Humidity
NEMA-4X enclosure, waterproof, chemical, and weather resistant.
Inputs
Direct Wired
Sensors
LEL
Oxygen
Carbon Monoxide
Hydrogen Sulfide
Carbon Dioxide.
4-20 mA Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI sensors are available with
4-20 mA signals. Wiring distances up to 8,000 feet.
Sampling Methods Diffusion and sample draw heads available.
Outputs
Relays
    Two flexible, programmable Form-C (C, NO, NC) relays per channel, plus five common relays (Fail, Alarm-1, Alarm-2, Alarm-3, Alarm-Any). Common relays may optionally be assigned to function as additional channel alarm relays, providing for up to three alarm relays per channel. 10A contact rating.
4-20 mA Signal output, 4-20 mA (maximum load impedance 500 ohms), per channel
24 VDC Modbus format RS-485 serial output of all channel data, including gas reading and alarm status.
RS-485 2 x 8 Alphanumeric display with backlighting.
Display
    4 x 20 backlit LCD display
Audible Built-in audible alarm, 94 dB, mounted on enclosure
Coded output: pulsing = gas alarm, steady = fail
Visual 1. Alarm LEDs (on Display PCB)
Alarm 1, yellow
Alarm 2, orange
Alarm 3, red
Fail, yellow
2. Green Pilot LED to indicate AC power connected (on Display PCB)
3. An optional 24 VDC NEMA 4X strobe mounted to top of case.
Power
115 VAC & 220 VAC, or 24 VDC nominal, battery backup option available
Warranty
One year materials and workmanship.

•"M2" Seiries
Stand Alone Explosion Proof Transmitter
Features
  • Operates independent of a controller
  • Direct digital readout on backlit LCD
  • Available for LEL, H2S, CO, and O2
  • 4-20 mA & digital Modbus outputs standard
  • Non-intrusive calibration via magnetic wand
  • 2 fully programmable alarm relays & fail relay
  • H2 specific LEL version available
  • Infrared combustible version available
  • Patented water repellent sensor coating
  • User friendly setup push buttons & LCD menus
  • CSA, and/or UL approved
Applications
  • Petrochemical plants
  • Refineries
  • Offshore drilling platforms
  • Water & wastewater treatment plants
  • Offshore oil rigs
  • Pulp & paper mills
  • Gas, telephone, & electric utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
The RKI M2™ is a state-of-the-art transmitter that can operate as an independent, stand-alone system or as part of a system connected with an analog or digital signal to virtually any controller, PLC, or DCS. The M2 series detects LEL combustibles, oxygen, hydrogen sulfide, or carbon monoxide. It utilizes a magnetic wand technique for performing non-intrusive calibration. The M2 provides an automatic zero drift correction feature, which results in more stable readings and reduces the need for adjustments due to sensor aging.

The M2 housing does not need to be opened for zeroing or calibration, making it unnecessary to declassify the area for routine maintenance. Internal push-buttons can also be used if the housing is opened. It is designed so that a complete field calibration can be performed by one person. The stainless steel flame arrestor that covers the sensor (LEL, H2S, CO, or XP Oxygen) is water repellent with a special patented water resistant coating.

The M2 provides a 4-20 mA output in addition to a Modbus digital output. It also has two levels of alarm with relays, plus a fail alarm with a relay. A digital display of the gas concentration, as well as alarm and status lights can be viewed through the front window.

The M2 represents the latest leading edge technology in sensor / transmitters today.

Sensors

LEL

02

H2S

CO

CO2

CH4

HC

Types

Catalytic

Galvanic cell

Electrochemical

Infrared

Part#

65-2610RK
65-2610RK-05

65-2611RK (H2 Specific)

65-2611RK-05

65-2613RK
65-2613RK-05 *65-2614RK

65-2615RK-05

65-2616RK-05

65-2630RK-03

65-2619RK-CH4

65-2619RK-HC

Measuring Ranges

0 - 100 % LEL

0 - 25.0 % Vol

0 - 100 ppm

0 - 300 ppm

0 - 5% Vol

0 - 100% LEL

Weather Resistant

Patented water repellent sensor coating (*Except for 65-2613RK and 65-2614RK)

Outputs

Analog

4-20 mA signal, into 500 ohms impedance max, corresponding to 0 - full scale

Digital

Modbus RTU output standard, fully configurable, 2-wire RS-485, 1200 to 19.2k baud

Alarms

Alarm Settings

Fully programmable alarm setpoints, increasing / decreasing, latching /
self-resetting, on delays, off delays, normally energized or de-energized,
programmable deadband, programmable smoothing filter

Alarm Indication

Visual LEDs. Alarm 1, Amber; Alarm 2, Red; Fail, Red

Relays

5 amp form C  contacts for alarm 1, alarm 2, and fail

Physical

Dimensions

Height: 8.5  (215 mm), Width: 5.2  (132 mm), Depth: 4.5  (114 mm)

Display

Alphanumeric display with backlighting. 8 characters per line;
2 lines for gas concentration readout, plus user-friendly calibration and setup

Enclosure

Explosion proof for Class I, Div 1, Groups B, C, D.

Enclosure Rating

NEMA 4, explosion proof, watertight, cast aluminum with o-ring seal and epoxy
powder coating

Controls

Magnet used for calibration functions. Calibrates without opening the housing.
Internal push-button controls also available for calibration and setup

Operating Environment

Operating Temperature

-4°F ~ 122°F (-20°C ~ 50°C)

Relative Humidity

5 - 95% RH non-condensing

Location

Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D. (Oxygen available in non XP version also)

Operating Voltage

19 VDC - 30 VDC

Approvals

65-2610RK-05
65-2611RK-05
C CSA US

65-2610RK-05

65-2611RK-05

C UL US

65-2613RK-05
C CSA US

C CSA US

C UL US

Warranty

One year material and workmanship


•"S" Seiries
Diffusion Sensor/Transmitter
features
  • Explosion proof housing
  • Patented water repellent sensor coating
  • Operates independent of a controller
  • Available for LEL, H 2 S, CO, O 2 , and ppm HC
  • Long life sensors (2 + years typical)
  • Competitively priced
Applications
  • Petrochemical plants
  • Refineries
  • Offshore Drilling Platforms
  • Water & wastewater treatment plants
  • Pulp & paper mills
  • Gas, telephone, & electric utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
  • Chemical storage buildings

The RKI "S" series gas sensor/transmitters are highly reliable and very cost effective basic 4-20 mA transmitters for detection of common gas hazards. The "S" series transmitters are available for LEL, Oxygen, H2S, CO, or for 0 - 500 ppm Hydrocarbon detection (for various fuels or solvents). The electronics are encased inside a potted package to avoid damage from mechanical abuse or corrosion, and the amplifier is installed inside an explosion-proof enclosure. Sensors for LEL, H2S, CO, and ppm HC are explosion-proof with flame arrestors. The Oxygen sensor utilizes an internal I.S. barrier, so all 5 versions are designed for use in hazardous atmospheres.
The only tools required to calibrate the "S" series are a voltmeter, screwdriver, and cal gas. The zero and calibration functions are performed by adjusting potentiometers on the amplifiers. The amplifier has test jacks for connection of a voltmeter for calibration purposes, and the sensor response is viewed on the voltmeter as a 100mV to 500mV signal. Field calibration can be performed easily and quickly by one person.
The "S" series transmitters can be used either indoors or outdoors. The flame arrestors utilize a patented coating which makes them water repellent, and splash guards are also available for use in very wet environments.
The transmitter operates from 24 VDC (10.5VDC to 30 VDC), and provides a 4-20mAsignal which can be connected to a wide variety of controllers.

Part # LEL
65-2400RK
65-2400RK-05

O2
65-2513RK
65-2516RK
65-2504RK*
H2S
65-2422RK-05
CO
65-2432RK-05
Min Operating
Voltage
11 VDC
Max Operating
Voltage
30 VDC
Max Current
Draw
200 mA
(power wires)
25 mA (signal wires)
3 or 4 wires
25 mA
(2 wire system)
Signal Output 4 - 20 mA signal
Response
Time
30 seconds to 90%
of concentration
20 seconds to 90%
of concentration
45 seconds to 90% of concentration 30 seconds to 90% of concentration
Operating Environment
Location Indoor or outdoor.
Explosion proof for
Class , Div. 1,
Groups B, C, and D.
Indoor or outdoor.
Explosion proof
housing and
intrinsically safe sensor.
Indoor or outdoor. Explosion proof for Class I, Div. 1,
Groups B, C, and D.
Temperature -40 to 185° F -4 to 113° F
Humidity 0 - 99% RH,
non condensing
Housing Aluminum Explosion
proof enclosure
Sensor
Type Catalytic
Combustion
Galvanic Cell Electrochemical
Life Expectancy 1 to 2 years with normal
intermmittent exposure to
flammable gas
2 years normal service 2 years normal service when intermittently exposed to H2S 2 to 3 years
normal service
Controls
Zero Sets transmitter output to 4 mA with 0% LEL output from combustible sensor Sets transmitter output to 4 mA with an inert gas (zero)
output from
O2 sensor
Sets transmitter output to 4 mA with zero output from H2S
sensor
Sets transmitter output to 4 mA with zero output from CO sensor
Span Sets transmitter output to 20 mA with 100% LEL output from combustible sensor Sets transmitter output to 17.44 mA with 20.9% Vol. O2 (fresh air) output from O2 sensor Sets transmitter output to 20 mA with 100 ppm output from H2S sensor Sets transmitter output to 20 mA with 300 ppm output from CO sensor
Operating Voltage
11 VDC to 30 VDC
Approvals
65-2400RK UL
65-2400RK-05 C/CSA/US
65-2516RK C/CSA/US C/CSA/US
Warranty
One year materials and workmanship